FTR100 Filter Timer


FTR100 Model devices are designed and produced to use in cleaning systems of filters in industrial environments.
Supply: 100-240VAC/DC, 24VAC/DC
Power Consumption: 6W, 7VA
Options: 8, 16 or 24
Ambient Temp.: -10...+55° C
Enclosure: IP65

Description:
FTR100 model devices are designed to be used on filter cleaning systems used on industrial setting, and there are microprocessor controlled timers. The device is consist of a main control device and output units controlled by this device. Relays used for each output units are able to switch 250VAC 10A for resistive power.

FTR100 model devices can be programmed to work as single group or at most 8 groups according to the demand of the user. Thanks to the number of relays which can be selected as a software, the user can create as many sequence as s/he needed. 8 outputs on groups can change each other’s pulse duration and waiting period, and can skip waiting period at the end of sequence.

FTR100 model devices have 100-240V AC/DC or 24V AC/DC supply voltage according to the demand of the user. The pulse valve timers in other words filter electronic timers has different channel output units.

Model No / Order Coding: 
ModelSupply VoltageChannel Output UnitOutput Type
FTR100-0-08-R/T* 100-240V AC 8 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-16-R/T* 100-240V AC 16 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-24-R/T* 100-240V AC 24 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-32-R/T* 100-240V AC 32 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-40-R/T* 100-240V AC 40 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-48-R/T* 100-240V AC 48 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-56-R/T* 100-240V AC 56 Channel Output Unit Relay(R) or Transistor(T)
FTR100-0-64-R/T* 100-240V AC 64 Channel Output Unit Relay(R) or Transistor(T)
*If your supply voltage is 24AC/DC, please order as "FTR100-1-XX-X" instead of "FTR100-0-XX-X".
*When ordering, please indicate the last digit as "R" for Relay Output or "T" for Transistor Output.


Technical Features (FTR100 Filter Timer for Pulse Valves)
Application: Timing of Pulse Valves in Dust Collection Systems
Supply Voltage: 100-240V AC or 24V AC/DC
Lifecycle: 100 years or 100.000 renewals
Accuracy: %0,2
Sampling Time: 400ms
Group Number: Min 1, Max 8
Ambient Temperature: -10°C…+50°C
Output Relay Power: Resistive Load, 250VAC; 10A Max
Adjustments: Pulse, delay and group transition time (0,0....999,9 seconds)

Important: The transistor outputs are fast and long lifecycle. Relay outputs are slow and have a shorter lifespan. However, the transistor outputs are not isolated, the output of the relays is isolated. Therefore, you can not use transistor outputs at every voltage and current. However, you can use relay outputs at any voltage of AC-DC 24V or 220V.

Usage: Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters, cement industry, ceramic industry, petrochemical industry, feed industry, sand blasting machines, power plants, concrete plants etc.